Dini Argeo TE C6 Series Electronic Weighing Scales – Safe, Accurate EX Stainless Steel 304 Platform for Harsh Environments
The Dini Argeo TE C6 Series electronic weighing scale is a premium product line that integrates ATEX-certified explosion-proof load cells, fully constructed from durable, polished stainless steel 304. It provides a safe and precise weighing solution for areas with strict hygiene requirements or high explosion risks. This is the optimal choice for factories, chemical zones, or hazardous environments.
Outstanding Advantages of the Dini Argeo Explosion-Proof TE C6 Series Scale
- Explosion-proof load cell with C6 6000e approval, made from aluminum, certified to international OIML R60 standards with IP67 protection against dust and water.
- Fully constructed from stainless steel 304 including the frame, weighing platform, and mechanics, ensuring exceptional durability and corrosion resistance in humid or chemical environments.
- Adjustable stainless steel feet with anti-slip plastic pads and precise leveling system.
- 3-meter connection cable with anti-interference shielding, IP65 rated, ensuring stable signal transmission in harsh industrial conditions.
- Accuracy classes C3MI, C6, C6MR, meeting strict requirements for precision in electronic weighing.
Note: The Dini Argeo TE C6 EX scale can be upgraded to an ATEX explosion-proof version as required:
- CCATEX: Individual ATEX certification for each explosion-proof load cell.
- DCATEXMECH: ATEX conformity declaration for the entire platform, applicable when the indicator is not purchased (refer to the compatible Dini Argeo indicator ATEX certifications).
Multi-Interval Version -MI for Optimized Accuracy
The TE C6 Series offers a 2x3000e multi-interval approved version, providing the ideal combination of high accuracy and ease of use for applications requiring C3-certified weighing equipment.
Unlike standard multi-range approvals, the -MI multi-interval version of the Dini Argeo electronic scale allows automatic adaptive resolution adjustments based on the measured weight, enhancing precision without sacrificing user convenience.
Note: The -MI version must be paired with Dini Argeo DFW or 3590 series indicators, DiniCal calibration service, and ECEM2MI approval package.
>> Learn more about Dini Argeo weighing indicators
Technical Specifications – Dini Argeo TE C6 Stainless Steel 304 EX Scale
- Entire structure made from polished satin AISI 304 stainless steel, offering excellent corrosion resistance.
- Aluminum load cell, IP67 rated for dust and water protection.
- Connection via 3-meter shielded cable, IP65 rated for harsh environments.
- Accuracy classes: C3MI, C6, C6MR, OIML R60 C6 6000e, suitable for both commercial and industrial weighing.
- Optional upgrades include full AISI 316 stainless steel structure or custom sizes and capacities as required.
Specifications EX Platforms
| Multi Interval Version “-MI” The T and TE series scales are available in a 2x3000e multi-range approved version, the best combination of accuracy and ease of use for a class C3 approved weighing instrument. Compared to the more common multi-range type approval, the multi-interval type approval offers ADAPTIVE measurement resolution, which automatically varies by adjusting to the weight being measured. NOTE: Multi-interval models are distinguished by the final “-MI” abbreviation and must be paired with a DFW or 3590 series Dini Argeo indicator, DiniCal calibration service and ECEM2MI approval service. | Options for ATEX Version CCATEX: ATEX certificate for each load cell.DCATEXMECH: ATEX declaration for the platform (for the load cells ATEX declaration see CCATEX-1 code).Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications. | Available Upon Price Estimate Special sizes and capacities. Structure in AISI316 stainless steel. |
| Code | l x w x h (mm) | Max (kg) | d (g) | M (g*) | d HR (g)* |
|---|---|---|---|---|---|
| TSE3C6 | 230x330x93 | 3 | 0,5 | See table below | 0,1 |
| TSE3C6-MI | 230x330x93 | 3 | — | 0,5/1 (Multi interval) | — |
| TSE6C6 | 230x330x93 | 6 | 1 | See table below | 0,2 |
| TSE6C6-MI | 230x330x93 | 6 | — | 1/2 (Multi interval) | — |
| TSE12C6 | 230x330x93 | 12 | 2 | See table below | 0,5 |
| TSE12C6-MI | 230x330x93 | 12 | — | 2/5 (Multi interval) | — |
| TTE6C6 | 330x330x93 | 6 | 1 | See table below | 0,2 |
| TTE6C6-MI | 330x330x93 | 6 | — | 1/2 (Multi interval) | — |
| TTE12C6 | 330x330x93 | 12 | 2 | See table below | 0,5 |
| TTE12C6-MI | 330x330x93 | 12 | — | 2/5 (Multi interval) | — |
| TTE30C6 | 330x330x93 | 30 | 5 | See table below | 1 |
| TTE30C6-MI | 330x330x93 | 30 | — | 5/10 (Multi interval) | — |
| TQE12C6 | 400x400x115 | 12 | 2 | See table below | — |
| TQE12C6-MI | 400x400x115 | 12 | — | 2/5 (Multi interval) | — |
| TQE30C6 | 400x400x115 | 30 | 5 | See table below | 1 |
| TQE30C6-MI | 400x400x115 | 30 | — | 5/10 (Multi interval) | — |
| TQE60C6 | 400x400x115 | 60 | 10 | See table below | 2 |
| TQE60C6-MI | 400x400x115 | 60 | — | 10/20 (Multi interval) | — |
(*) Divisions obtainable only with the relative options, in combination with Dini Argeo weight indicator.
| C3 | C6 | |||||
| ECEM2 MI 2x3000e | ECEM-C6 6000e | ECEM2-C6 6000+6000e | ||||
| Max (kg) | e (g) | Max (kg) | e (g) | Max (kg) | e (g) | |
| TSE 230x330x90mm | 3 | 0,5/1 | 3 | 0,5 | — | — |
| 6 | 1/2 | 6 | 1 | 3/6 | 0,5/1 | |
| 12 | 2/5 | — | — | — | — | |
| — | — | 12 | 2 | 6/12 | 1/2 | |
| TTE 330x330x90mm | 6 | 1/2 | 6 | 1 | 3/6 | 0,5 |
| 12 | 2/5 | — | — | — | — | |
| — | — | 12 | 2 | 6/12 | 1/2 | |
| 30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
| TQE 400x400x115mm | 12 | 2/5 | — | — | — | — |
| — | — | 12 | 2 | 6/12 | 1/2 | |
| 30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
| 60 | 10/20 | 60 | 10 | 30/60 | 5/10 | |
Available Versions
| Part # | Description | List Price | Cart/Quote | |
|---|---|---|---|---|
![]() | TSE3C6 | Platform made of AISI304 stainless steel, IP67, Max=3kg, d=0,5g, 230x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TSE3C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=3kg, e=0,5/1g, 230x330mm loading surface. Aluminium load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TSE6C6 | Platform made of AISI304 stainless steel, IP67, Max=6kg, d=1g, 230x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TSE6C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=6kg, e=1/2g, 230x330mm loading surface. Aluminium load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TSE12C6 | Platform made of AISI304 stainless steel, IP67, Max=12kg, d=2g, 230x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TSE12C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=12kg, e=2/5g, 230x330mm loading surface. Aluminium load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TTE6C6 | Platform made of AISI304 stainless steel, IP67, Max=6kg, d=1g, 330x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TTE6C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=6kg, e=1/2g, 330x330mm loading surface. Aluminium load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TTE12C6 | Platform made of AISI304 stainless steel, IP67, Max=12kg, d=2g, 330x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TTE12C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=12kg, e=2/5g, 330x330mm loading surface. Aluminum load cell. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TTE30C6 | Platform made of AISI304 stainless steel, IP67, Max=30kg, d=5g, 330x330mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TTE30C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=30kg, e=5/10g, 330x330mm loading surface. Aluminum load cell. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TQE12C6 | AISI304 stainless steel platform, IP65, Max=12kg, d=2g, 400x400mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TQE12C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=12kg, e=2/5g, 400x400mm loading surface. Aluminum load cell. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TQE30C6 | Platform made of AISI304 stainless steel, IP65, Max=30kg, d=5g, 400x400mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TQE30C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=30kg, e=5/10g, 400x400mm loading surface. Aluminum load cell. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult | |
![]() | TQE60C6 | Platform made of AISI304 stainless steel, IP67, Max=60kg, d=10g, 400x400mm loading surface. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. | Consult | |
![]() | TQE60C6-MI | Platform made of AISI304 stainless steel, IP67, multi interval approved, Max=60kg, e=10/20g, 400x400mm loading surface. Aluminum load cell. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. | Consult |
Practical Applications of the Dini Argeo TE C6 ATEX Explosion-Proof Scale
Widely used in:
- Food processing and seafood production areas with stringent hygiene requirements.
- Chemical plants, pharmaceutical factories, or any location with a high risk of explosion.
- Automated weighing systems in environments requiring high-quality explosion-proof load cells.
- Gas stations, laboratories, or warehouses with strict safety standards.
FAQ – Frequently Asked Questions About the Dini Argeo TE C6 EX Scale
1. Is the Dini Argeo TE C6 electronic scale suitable for outdoor use?
The scale is IP67 rated for dust and water resistance, making it suitable for outdoor environments. However, proper installation and operational guidelines should be followed to ensure long-term durability.
2. Can the ATEX explosion-proof scale be integrated into automation systems?
Absolutely. The TE C6 Series easily connects with ATEX-certified Dini Argeo indicators, allowing seamless integration into control systems or data management software.
3. Is it possible to order the stainless steel 304 platform in custom sizes?
Yes, customers can customize the scale’s dimensions and capacities based on their specific needs. Additionally, options include upgrading to an AISI 316 stainless steel structure or fully welded IP68/IP69K load cells for high-pressure washdown or continuously wet environments.
“Investing in the right Dini Argeo EX scale helps your business operate safely, accurately, and efficiently in the long term.”
For more information, please contact Golden Lotus Measurement Equipment Co., Ltd – Phone: 028 0906 903 369 / 0901 334 669 – or visit our website: https://hoasenvang.vn/en/















